System III Impressed Current Cathodic Protection Balcony concrete restoration due to rebar
corrosion may be the most expensive and inconvenient project a condominium
will face. Therefore a proven, economical long-term solution is needed.
CPT's System III impressed current cathodic protection system is the answer.
System III Will Stop The Corrosion CPT's System III has been developed over
the past 20 years to reverse the corrosion process. Utilizing our proprietary
C2A conductive mastic anode, System III provides powerful and permanent
corrosion protection. Our long life carbon conductive mastic tenaciously
bonds to the concrete surface to deliver a prescribed amount of DC current
directly through the concrete to reinforcing steel. C2A conforms to all
concrete surface irregularities thereby increasing system flexibility and
perfectly blending itself into the existing structure.
System Components
Superior Technology System III is controlled by a sophisticated
yet simple network of controls. A heavy-duty rectifier converts AC to DC
power, while utilizing approximately the amount of energy needed to run
a 120-watt light bulb. The DC current is distributed through a main junction
box to zones occupied by anode junction boxes. At each level the system
is calibrated to deliver calculated amounts of current to each balcony
zone. Platinum anode wires run off of header lines to deliver current to
the conductive mastic. Internal feedback controls consisting of imbedded
reference electrodes and a remote monitoring unit (RMU) allow the system
to be monitored on site or from a remote station.
Distinct Advantages for New and Exitsing Structures System III separates itself from the pack with recognizable key advantages. Innovative design and manufacturing techniques have enabled CPT to provide a high performance system at a relatively low cost. Due to the ease of applying CPT's proprietary conductive mastic, installation costs are lower than comparable impressed current cathodic systems utilizing sawslotting or overlays. Easy access to anodes, mastic and control systems ensure future low cost maintenance the competition just can't match. Consequently, CPT's reliable performance, customer satisfaction and proven history are unequaled. "There is no question that properly installed and activated cathodic protection systems halt corrosion and corrosion induced concrete damage in salt-contaminated above ground reinforced concrete structures.” Consumption Rate
Lasting Protection The C2A carbon mastic anode provides an
unsurpassed technology to cathodically protect balconies and similar structures.
Years of monitoring actual current densities have indicated low output
values on average of
The graph plots anode consumption rates using high level laboratory testing of 2.0 mA/sq. ft. versus actual field analysis. |
|||||